<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-23 02-02-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 67 kHz 14673 9,1733
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 5,16 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 67 kHz MIN: 10 kHz % above 76 kHz: 9,1733 Acquired: 2025/05/23 2.01.10 Total samples: 14673 Equivalent time: 0:12:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,9 dBr MIN: 3,7 dBr AVE: 5,16 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2025/05/23 2.01.10) 01.48 01.50 01.52 01.54 01.56 01.58 02.00 0 2 4 6 Pm [dBr]